Turbines: Montana 5.0m

< return

Passaat 3.1m

Passaat

Montana 5.0m

Montana

Alizé 7.1m

Alizé
Documentation and Performance Read >> Read >> Read >>
Rotor diameter 10.2ft (3.1m) 16.4ft (5.0m) 23.3ft (7.1m)
Swept area 82ft2 (7.7m2) 211ft2(19.6m2) 426ft2(39.6m2)
Delivered power (AC to grid) @ proposed AWEA standard wind speed of 11m/s (24.6mph) ~500W (determined from actual US data) 2,300W (determined from actual US data) 9,200W (determined from actual US data)
Peak power (AC) ~1,400W @ 36mph (16m/s) ~5,000W @ 38mph (17m/s) ~12,000W @ 34mph (15m/s)
Estimated system efficiency (for annual energy calculation) 0.15 0.20 0.25
Estimated Annual Energy Output (kWh) 760 kWh @ 4m/s (8.9mph)
1,480 kWh @ 5m/s (11.2mph)
2,560 kWh @ 6m/s (13.4mph)
2,600 kWh @ 4m/s (8.9mph)
5,000 kWh @ 5m/s (11.2mph)
8,700 kWh @ 6m/s (13.4mph)
6,500 kWh @ 4m/s (8.9mph)
12,700 kWh @ 5m/s (11.2mph)
21,900 kWh @ 6m/s (13.4mph)
Number + length of blades 3 @ 4.9ft (1.5m) 3 @ 7.7ft (2.35m) 3 @ 10.8ft (3.3m)
Blade airfoil NACA 4418 NACA 4415 NLF 416
Blade material Fiberglass-reinforced polyester Fiberglass-reinforced epoxy Fiberglass-reinforced polyester or epoxy
Blade rotation Clockwise (viewed upwind of turbine, from hub toward tail vane) Clockwise Clockwise
Alternator design (Grid-tie turbines) 12-pole PM,
Star (wye) coil wiring
18-pole PM,
Star (wye) coil wiring
R(Φ-Φ)=9.1 Ohms
18-pole PM,
Star (wye) coil wiring
R(Φ-Φ)=5.2 Ohms
L=74 mH @ 50Hz
Alternator output
(Grid-tie turbines)
Normal operation:
180-750 RPM
=18-75 Hz
80-350 VAC
No load (freewheeling):
@ 750 RPM =75 Hz
Voc = 500 VAC (est)
Normal operation:
80-350 RPM
=12-53 Hz
80-400 VAC
No load (freewheeling):
@ 350 RPM = 53 Hz
Voc = 468 VAC (est)
Normal operation:
50-300 RPM
=7.5-45 Hz
80-450 VAC
No load (freewheeling):
@ 350 RPM = 53 Hz
Voc = 673 VAC (est)
Load controllers
(for grid-tie turbines)
SMA WBP-Box 400 + diversion load, 400VDC output limit SMA WBP-Box 500 + diversion load, 500VDC output limit SMA WBP-Box 500 + diversion load (one per inverter), 500VDC output limit
SMA WindyBoy inverters
(for grid-tie turbines)
WB1700 (1.7kW, for high-wind sites, non-UL)
or
WB1100 (1.1kW, for low-wind sites, non-UL)
WB5000US (5kW, for high-wind sites)
or
WB3000US (3kW, for low-wind sites)
2 x WB6000US (12kW)
or
3 x WB5000US (15kW, for balanced 3-phase connection)
Grid-connected
voltage options
1Φ 240VAC (Φ-to-Φ) 1Φ 240VAC (Φ-to-Φ), or
3Φ 208VAC (Φ-to-Φ), or
3Φ 277VAC (Φ-to-N, WB5000US only)
1Φ 240VAC (Φ-to-Φ), or
3Φ 208VAC (Φ-to-Φ), or
3Φ 277VAC (Φ-to-N)
For Grid-tie with Battery backup add 1 or 2 x SMA SunnyIsland 5048U inverter(s) to grid-tie systems add 1 or 2 x SMA SunnyIsland 5048U inverter(s) to grid-tie systems add 1 or 2 x SMA SunnyIsland 5048U inverter(s) to grid-tie systems
Load controllers
(for battery-charging only turbines)
FWE controller + matched diversion load FWE controller + matched diversion load FWE controller + matched diversion load
Battery-charging voltage options 24 or 48 VDC 48 VDC 120 VDC
Rotor axis angle 10° 10° 7°
Pitch control & Hub design Fixed pitch, Rigid hub Fixed pitch, Rigid hub Fixed pitch, Rigid hub
Braking system Mechanical: Off-axis alternator mount + inclined-hinge tail vane furling
Electrical: Alternator brake switch at tower base
Mechanical: Off-axis alternator mount + inclined-hinge tail vane furling
Electrical: Alternator brake switch at tower base
Mechanical: Off-axis alternator mount + inclined-hinge tail vane furling
Electrical: Alternator brake switch at tower base
Yaw control Passive alignment by tail vane Passive alignment by tail vane Passive alignment by tail vane
Towers Tilt-up, 4" or 5" pipe: 85', 106' or 127' Self-supporting lattice (SSL): 80' to 160' Self-supporting lattice (SSL): 80' to 160'
Total weight of assembled turbine 165lb (75kg) 440lb (200kg) 847lb (385kg)
Alternator weight 55lb (25kg) 242lb (110kg) 506lb (230kg)
Blade weight 26lb (12kg) 66lb (30kg) 132lb (60kg)
Tail + Frame weight 57lb (26kg) 79lb (36kg) 169lb (77kg)
Documentation and Performance Read >> Read >> Read >>